Oxysys 4000/4500[Mediconet Co., Ltd.]

Oxysys 4000/4500[Mediconet Co., Ltd.]


Negotiable Min Order Quantity Unit

Required Quantity
Place of Origin
Payment Terms
Negotiable
Production method
Negotiable
Shipping / Lead Time
Negotiable / Negotiable
Keyword
chamber, hbot, hyperbaric chamber, hyperbaric oxygen chamber, medical health supplies, medical products & equipment, medical supplies manufacturer
Category
Other Health Care Products
tK Meet
tK Meet

Apply a video call to the Supplier

SEND TO SUPPLIER INQUIRY

MEDIconet Co., Ltd.

Country / Year Established
South Korea South Korea /
Business type
Others
Verified Certificate

13

TRADE TOWER

DUNS

Product name Oxysys 4000/4500[Mediconet Co., Ltd.] Certification -
Category Other Health Care Products Ingredients -
Keyword chamber , hbot , hyperbaric chamber , hyperbaric oxygen chamber , medical health supplies , medical products & equipment , medical supplies manufacturer Unit Size -
Brand name - Unit Weigh -
origin Stock -
Supply type - HS code -

Product Information

Oxysys 4000/4500[Mediconet Co., Ltd.]

[Korean manufacturers/Korean suppliers/Korean products/Korean trade/Korean company]

 

Features

Distinctive feature of Oxysys 4000, 4500
Devised, developed and produced by Mediconet.
Outstanding features count most in convenience, practical functions and safety.

  • Two controllable pressures : 2psi and 4psi.
  • Safety knob to release pressure in emergency.
  • The most widely installed model in Korea and Japan.
  • Air conditioner to control temperature inside the chamber.
  • Wide and convenient transparent viewing window.
  • Adjustable timer for therapy.
  • Calling bell for the emergency.

Specification

Model Oxysys 4000 Oxysys 4500
Chamber usage one patient one patient
material Air-wall Tyupe. PU Air-wall Tyupe. PU
size / weight 200cm x Ø70cm, 22kg 200cm x Ø90cm, 25kg
normal pressure 2~4psi 2~4psi
Oxygen Generator fluid volume 5 Liters/min 5 Liters/min
purity 90%±5% 90%±5%
power consumption 230VAC±10%,50Hz, 600VA 230VAC±10%,50Hz, 600VA
size / weight W550 x H500 x D240, 30kg W550 x H500 x D240, 30kg
System fluid volume 85 Liter / min 85 Liter / min
specification Dual Head Oil-less 1/4hp Dual Head Oil-less 1/4hp
air filter Dual Dual
power consumption 230VAC±10%, 50Hz, 1000VA 230VAC±10%, 50Hz, 1000VA
size / weight W530 x H1178 x D455, 110kg W530 x H1178 x D455, 110kg
installation   1.5m x 2.5m 2m x 2.5m

B2B Trade

Price (FOB) Negotiable transportation -
MOQ Negotiable Leadtime Negotiable
Payment Options Negotiable Shipping time Negotiable

MEDIconet Co., Ltd.

Country / Year Established
South Korea South Korea /
Business type
Others

13

TRADE TOWER

DUNS

President
Yongdai Han
Address
#1-203 Wonju Medical Instrument Venture Center, Donghwa-ri, Munmak-eup,, Wonju-si, Gangwon-do, Korea
Product Category
Beauty & Personal Care
No. of Total Employees
1-50
Company introduction

Hyperbaric oxygen therapy
Oxygen is normally supplied by inhalation to our body.
It combines with hemoglobin inside of the red corpuscle(Bonded oxygen).

HBOT machine induces hyper pressure. It can increase the concentration of the melted oxygen in liquid(melted oxygen) The melted oxygen supplies directly to each cell. Adequate tissue perfusion and sufficient oxygen supply are two basic requirements for the healing responses of body. Without these the tissues enter a hypoxic state. Hypoxiz impairs many healing processes collagen synthesis, bacterial killing, angiogenesis, and epithelialization. Hypoxiz slows wound healing and favors bacterial growth.

HBOT accelerates normal healing mechanisms. The increased concentration of oxygen dissolved in plasma reaches tissues with poor or compromised vascular supply(increased diffusion distance). Tissue oxygenation is also improved as the resultant vasoconstriction decreases edema(decreased intercapillary distance)

HBOT stimulates the proliferation of fibroblasts and endothelial cells for at least three days post treatment.

Oxygen is delivered to the tissues at levels that actually inhibit bacterial growth. Tissue oxygen tension has been shown to be the most important local factor affecting oxidative leucocyte killing.

HBOT potentiates the growth and viability or many microorganisms while enhancing antibiotic effectiveness and the immune response of patient.

HBOT has been widely used in human such as sports medicine, plastic surgery, and health industries.

Main Product

Related Products

Other buyers also search

Membership Grade

BUYER

Biz Pro VIP

SELLER

Biz Pro VIP
팝업닫기
Live Chat A new message arrives
from a business partner.

No Data

  • There is no data to load
  • Check out the My tK > My Inquiries list.
  • After agreeing to the use of the Live Chat service, the list is printed only when there is at least one history of receiving or sending a Live Chat request.

If you have not yet agreed to use the Live Chat service,

You can use the Live Chat freely after agreeing to the use of the Live Chat service.

View more
View more